Breathing and heart-rate radar: the MR60BHA2 type

A handbook for 60 GHz radar kits reporting breath and heart rate, documented from the Seeed MR60BHA2 pages with the DFRobot C1001 as a cross-reference.

Vitals radar is the most constrained type in this directory. The vendor limits the function to a sleep scenario, fixes a short detection distance, and states that the algorithms are not open. This chapter is about respecting those boundaries rather than extending the claimed range.

The scene limit comes first

Seeed states that the respiratory and heart-rate function is recommended for use solely during sleep scenarios, and warns that use while seated at a desk or during exercise will produce significant inaccuracies. That is a hard constraint on the output contract, not a tuning hint. An application that needs vitals during activity is outside what this module documents.

The kit pairs a 60 GHz module with a XIAO ESP32C6 host carrying pre-flashed ESPHome firmware. The getting-started page gives a 1.5 m maximum for heartbeat detection and the same 1.5 m figure for combined breathing and heartbeat detection.

The installation geometry is specific

For sleep breathing and heart rate, Seeed specifies an inclined mount: 1 m directly above the head of the bed, tilted down 45 degrees toward the middle of the bed, with the distance from radar to the chest kept within 1.5 m and the radar normal aligned to the main detection position.

A ceiling mount that looks reasonable for presence sensing will not meet that geometry. The chest-distance requirement is the binding one, because the documented range is short. Mount, then verify that the reported values appear at the intended sleeping position before integrating them into anything else.

Know which values the library returns

The Arduino example exposes breath phase and heart phase through a phase call, and separate calls for breath rate and heart rate. Serial is opened at 115200. Seeed notes that a newer firmware build added human-presence detection and related human-object functions, so a host expecting presence alongside vitals should confirm the firmware version first.

Seeed publishes the firmware image, OTA tool, GUI, tiny-frame interface manual and module datasheet. It also states that the raw data and algorithms in its mmWave sensors are non-open source. The practical consequence is that the host can read and configure the published entities but cannot change the signal processing that turns chest movement into a rate.

Value Source call Boundary to record
Breath phase and heart phase Phase call Sleep scenario, aligned geometry
Breath rate Breath-rate call Within the 1.5 m chest distance
Heart rate Heart-rate call Within the 1.5 m chest distance
Presence Newer firmware with presence functions Confirm firmware version

Do not turn a rate into a diagnosis

A breath rate or heart rate from this module is a sensing output under a constrained scene, not a clinical measurement. This directory makes no diagnostic, treatment or efficacy claim. Persist the raw rate, the firmware version, the mounting geometry and the scene label together so a downstream user can see under which conditions a value was produced.

The DFRobot C1001 is documented in this directory with a vitals output as well as presence and fall. Its entry lists 60 GHz operation, 5 V at 100 mA and an 11 m vendor-claimed detection range; that range is a general detection figure and is not a stated vitals range, so it should not be read as one. Confirm the C1001 breathing and heart-rate geometry from its own wiki before designing around it.

No physical module was bench tested for this chapter. All figures above are documented values from the linked sources and must be confirmed on the bench before they are used as a measurement.