Fall-detection radar: the MR60FDA2 type
A handbook for 60 GHz radar kits that report a fall flag, documented from the Seeed MR60FDA2 pages with the DFRobot C1001 as a cross-reference.
Fall detection is a classification output, not a direct measurement. The radar sees a body change posture and distance; firmware decides whether that pattern is a fall. This chapter covers the mounting and scene constraints the vendor publishes, and the points where two official pages disagree.
Know what the kit actually contains
Seeed ships the MR60FDA2 as a 60 GHz fall-detection module on a XIAO ESP32C6 host with pre-flashed ESPHome firmware. The getting-started page states a 3 by 3 by 3 m coverage area and a 100 by 40 degree detection angle. The kit also carries an RGB LED and ambient light sensor, and exposes Grove GPIO for expansion.
The Arduino example uses a library call for fall status together with a human-presence status, so the application can distinguish no person, a person present without a fall, and a detected fall. The example opens serial at 115200. Seeed publishes the firmware image, an OTA upgrade tool, a GUI tool, a tiny-frame interface manual and a module datasheet. The raw data and algorithms are stated to be non-open source, so the host entities are configurable while the detection logic is not.
Mounting height is the two-page conflict
The two official Seeed pages give different height figures. The getting-started page specifies top mounting at 2.2 to 3.0 m with a maximum sensing radius of 2 m, with the radar face aligned to the detection direction. The parameter table gives an installation height threshold of 2.4 to 3.0 m and a fall-detection height band of 0 to 0.6 m.
These figures are not reconciled on either page. Record both, pick the installation height for your scene from the document that matches your firmware and enclosure, and validate the fall flag at that height. Do not present one page's number as if the other did not exist.
Seeed also asks for an open space and lists interference sources to keep out of the detection range. Fans, vents, curtains and thin walls belong on that list, as they do for presence modules. A cluttered room can produce a fall flag without a fall, or suppress a real one.
Treat the flag as an event, not a diagnosis
The fall output is a firmware classification of a sensing pattern. It is not a medical determination, and this directory makes no diagnostic or efficacy claim for it. A reasonable integration logs the fall flag together with presence state, timestamps and the mounting configuration so the event can be reviewed, and requires a second channel such as a user-confirmed alert before any high-consequence action.
The DFRobot C1001 is also documented with a fall output in this directory. Its entry lists 60 GHz operation, a presence, fall and vitals output set, 5 V at 100 mA, and an 11 m vendor-claimed detection range. That 11 m figure is a general detection range and is not a stated fall-detection range, so it should not be used to size a fall installation. Confirm the C1001 fall geometry from its own wiki before designing around it.
Build a repeatable test before trusting the flag
Site a test area that matches the vendor mounting figure, then walk through a scripted set of movements including sitting down quickly, bending to pick something up, and lying down deliberately. Record the flag, the presence state and the timestamp for each. Repeat after any firmware or enclosure change.
This is a functional check of the output contract, not a clinical validation. No physical module was bench tested for this chapter. All figures above are documented values from the linked sources and must be confirmed on the bench before they are used as a measurement.