Reading a mmWave radar datasheet: what each number actually allows

A radar datasheet is a list of physical limits and vendor conventions, not a feature list. Two modules can both claim "presence detection" while one reports nine distance gates and the other reports a single boolean.

This chapter decodes the rows that decide whether a module can do your job. Every figure quoted is from the official product pages collected in this directory; anything derived from them is marked as arithmetic.

Band and bandwidth are different rows

The band is the carrier frequency: 24 GHz or 60 GHz in this directory. It sets antenna size, how much the signal penetrates a plastic cover, and how much it is absorbed by walls and water.

The bandwidth is the sweep width inside that band, and it sets range resolution. The two rows are often printed next to each other, which makes them look interchangeable. They are not.

Module Band Published sweep bandwidth
HLK-LD2410 series 24.01-24.18 GHz 0.17 GHz
HLK-LD2450 24-24.25 GHz 250 MHz
Seeed MR60FDA2 and MR60BHA2 60 GHz not published as a static row

A wider sweep separates two targets that are closer together. A narrower sweep does not, no matter how large the detection range claim is.

Range resolution is arithmetic, not marketing

For a frequency-modulated continuous-wave radar, the theoretical range resolution is the speed of light divided by twice the bandwidth:

resolution = c / (2 x bandwidth)

Run that on the published rows:

The LD2450 datasheet publishes 0.75 m distance resolution, which is coarser than the 0.6 m bound. That is normal: the published figure includes windowing, processing and a rounded gate convention, so the formula tells you the floor, not the shipped number. Use the vendor figure for planning and the formula to understand why a module cannot resolve two people standing shoulder to shoulder.

Gates are a reporting convention

The ESPHome LD2410 component exposes nine distance gates numbered 0 to 8, with per-gate moving and still energy plus per-gate thresholds. The module's published still range is 6 m, and nine gates across roughly that range works out to about 0.75 m per gate.

That last sentence is arithmetic, not a datasheet row, and it is the useful part: it tells you the smallest distance band a threshold can address. Two people in the same gate are one blob to that control.

The LD2450 takes a different route. It publishes target coordinates at 0.75 m resolution rather than gate energy, so a host sees where a target is instead of how much energy each slice returned. Neither is a superset of the other.

Antenna count decides whether angle exists at all

The transmit and receive channel count is the row that limits everything downstream:

A wider field is not automatically better. A 120 degree field sees more of the room, including the corridor behind the doorway you were trying to exclude.

Field of view, detection angle and usable area

Published angles describe where the module can detect something, under the vendor's test conditions:

Three things shrink that field in a real room:

  1. Still detection is weaker than moving detection at the edges of the pattern.
  2. A person sitting at the edge presents less reflecting area than one standing in the centre.
  3. The mounting angle decides which part of the pattern points at the ceiling.

Treat the published angle as an outer bound and walk the room to find the usable area, as described in the validation checklist.

Report rate sets the automation budget

The LD2450 publishes 10 frames per second, which is 100 ms per update. The LD2410 publishes a frame rate that depends on the configured mode, and the ESPHome component exposes it as a stream rather than as a fixed promise.

The rate matters because automation delay is additive: a 100 ms frame, a 1 s debounce and a 2 s hold time give a response that is nowhere near 100 ms. Write the three numbers down before promising an instant light.

Current is an average until proven otherwise

Published currents in this directory are averages: 80 mA for the LD2410-AA and 120 mA for the LD2450, with the LD2450 page asking for a 5 V source above 200 mA.

An average with no peak figure is a design warning. Size the rail for the peak, keep the wiring short, and expect a marginal supply to appear as phantom targets rather than as a clean reboot.

Decode the phrases, not just the numbers

Datasheet phrase What it allows What it does not promise
Detection range 9 m A moving target can be seen at that distance in the test setup Still detection, or detection through furniture
Distance resolution 0.75 m Two reflectors closer than that merge Identifying which person is which
Plus or minus 60 degrees The antenna pattern reaches that angle Equal sensitivity across the field
10 frames per second A new sample every 100 ms End-to-end automation latency
80 mA average Typical draw over time Peak current at power-up or during a burst
Supports zones The firmware has a zone concept That the bridge publishes it

The last row is the one that costs the most money. A finished Zigbee sensor can support a vendor app feature that never crosses the bridge, and the attribute guide for that product is the place to confirm it.

The four numbers that decide feasibility

Before comparing prices, write these down for the job:

  1. The distance band you must separate, compared with the resolution.
  2. Whether you need angle, and therefore whether a single-channel module can work at all.
  3. The update rate the automation requires, including its own delay.
  4. The current and rail the installation can supply.

If any of the four fails, a different module will not fix it by being more expensive.

Related reading