Radar output types and the data contract with your host
Write down the output the automation needs before choosing a module. Presence, gate energy, coordinates and algorithm results are different contracts.
This chapter maps the six modules in this directory to the outputs their official pages document. It is a data-contract guide, not a performance comparison.
Four contracts are not four feature lists
| Contract | Modules that publish it | What the host receives |
|---|---|---|
| Presence or occupancy | HLK-LD2410, DFRobot C1001, Seeed MR60FDA2 and MR60BHA2 kits | a state, or a level on the OUT pin |
| Per-gate energy | HLK-LD2410 in engineering mode | moving and still energy for each distance gate |
| Multi-target coordinates and trajectory | HLK-LD2450, Ai-Thinker Rd-03D | target count with per-target x and y |
| Algorithm results | C1001, MR60FDA2, MR60BHA2 | fall, breathing and heart rate outputs |
The LD2450 publishes up to three moving targets at 10 frames per second with a 0.75 m distance resolution. The LD2410 publishes moving range, still range, detection distance, and moving or still energy through the ESPHome component. Neither description is interchangeable with the other.
A 60 GHz device does not automatically give you zones, multi-target tracking or fall detection. A 24 GHz module does not automatically give you raw samples. Those are firmware and interface decisions, and 60 GHz finished products often expose less data than a 24 GHz module does.
Coordinates are relative to the module
LD2450 x and y values live in the module's own frame. Mounting height and rotation decide what those numbers mean, and a re-mount invalidates any calibration done earlier. Record the mounting geometry in the host configuration so a later service visit does not silently rotate every reading.
Hi-Link recommends wall mounting the LD2450 at 1.5-2 m with a published field of ±60 degrees in azimuth and ±35 degrees in elevation. A ceiling mount points most of that field at the floor.
Decide what the bridge can carry
The transport between the host and the automation system is a second contract, and it is usually narrower than the first.
- A presence state survives almost every bridge because it is a boolean.
- Gate energy and target coordinates usually do not survive a generic Zigbee or Matter bridge, because there is no cluster for them.
- The MQTT payload for a UART module is defined by the host firmware, not by the radar module.
- Matter occupancy is a single cluster attribute, so a vendor zone map does not appear on the other side automatically.
The official Zigbee2MQTT page for the SONOFF SNZB-06P lists four exposed attributes and none of them is a distance gate, a coordinate or a zone. That device uses 5.8 GHz microwave sensing rather than mmWave radar, but it is a useful illustration of how little of a sensor's internal data a bridge publishes.
Algorithm results are sensing outputs, not measurements
Fall detection, breathing and heart rate figures are outputs for prototyping. DFRobot's official FAQ says the C1001 cannot count people in a room and carries a medical-use disclaimer on the product material. Seeed does not publish accuracy tolerances for the current firmware and lists no certificate number on the kit pages.
Do not turn these outputs into diagnostic claims, and do not assume that a fall entity working proves a fall configuration is correct: the MR60FDA2 quick start notes that fall detection has its own installation height and sensitivity.
Raw data and point clouds are a procurement question
Seeed states that the raw data and algorithms in its mmWave sensors are non-open source, and offers 3D point-cloud or interference-region settings as a customisation service rather than a public API. If a project needs raw samples, confirm on the official page that a data interface is exposed before shortlisting the hardware. A point cloud is not a property of the carrier frequency.