A repeatable validation checklist for radar installations

Record the room, the firmware and the mounting geometry with every reading. Without those three, a tuning result cannot be reproduced after a re-mount.

This chapter is a field checklist built from the installation and interference conditions published by the radar vendors. We have not bench tested any device, so no figure here is our own measurement and no device is ranked.

Write down the baseline before the first reading

A result without this header is not reproducible. It also hides the case where a firmware update, rather than the installation, changed the behaviour.

Take three readings before changing a threshold

Set the per-gate thresholds between the second and third readings, and cap the maximum gate at the room boundary. Changing a global sensitivity value instead of the gate thresholds usually just moves a false trigger to another distance. Sensitivity, gate thresholds and the no-person delay are three separate controls.

Walk the boundary instead of trusting a datasheet range

Vendor claims in this directory include 9 m moving and 6 m still range for the LD2410, 6 m for moving targets on the LD2450, 11 m for the C1001, and 6 m motion with 3 m presence for the MR60FDA2. Hi-Link publishes separate figures for 3 m and 6 m mounting heights, which is why a ceiling figure is not a wall figure.

Walk the real boundary with the intended mounting position and record where detection starts and stops. Record the usable field of view, the observed reporting rate, and how many targets the tracker keeps before dropping one. These are observations of your room, not corrections to the datasheet.

Work through the interference list by source

Source Vendor pages that list it
Fans, air-conditioning outlets, curtains, thin walls Hi-Link LD2410, DFRobot C1001, Ai-Thinker Rd-03D
Thin walls, metal reflections, multiple radars close together Hi-Link LD2450
Glass, thin wooden boards, vibrating mounting locations Seeed MR60FDA2
Body movement, desk posture, exercise, nearby radars Seeed MR60BHA2
Reflective surfaces DFRobot C1001

Hi-Link notes that the LD2410 can work inside a plastic enclosure without an opening. That is a statement about housings, not permission to point a radar through a wall.

Treat mounting geometry as a tuning input

A new orientation changes which gates see which surfaces, so recheck every threshold after moving a module. Also verify gateway loss, reconnection and a fresh report before calling an installation done; an unchanged occupancy value can be legitimate, and device availability is a separate signal.

What this checklist cannot prove

Tuning cannot create angular resolution on a 1T1R module, cannot make a moving-target tracker report a stationary person, and cannot turn a fall or breathing output into a diagnostic measurement. Choose the right output type before tuning it.

We also do not publish false-trigger rates, response delay comparisons, prices or market share estimates for these modules. A future bench test would need the same room, the same mounting geometry and a recorded count of missed detections and unwanted triggers before any of those comparisons would mean anything.