Multi-target tracking radar: LD2450 and Rd-03D

A handbook for 24 GHz modules reporting up to three moving targets as relative coordinates and speed, sourced from LD2450 and Rd-03D documents.

A tracking module answers where targets are, not just whether a room is occupied. That changes the integration job: coordinates are relative to the sensor, the target count is capped, and stationary people are a separate case from moving ones. This chapter covers those boundaries and the configuration paths the vendors actually publish.

Two modules, two documented coordinate stories

Hi-Link publishes the LD2450 as a 24 to 24.25 GHz FMCW module with one transmit and two receive antennas. It states a 6 m maximum range, a 60 degree azimuth and 35 degree elevation window, 0.75 m distance resolution, 10 frames per second, and tracking of up to three moving targets with x and y coordinates and speed. Serial default is 256000 baud, one stop bit, no parity. Supply is 5 V with over 200 mA of available current and 120 mA average draw.

ESPHome states the x range as minus 3000 to 3000 mm and the y range as 0 to 6000 mm, with a maximum of three targets. It strongly recommends hardware UART pins in order to sustain the 256000 baud rate. The component also exposes up to three configurable zones, including an exclude mode, and a presence timeout.

Ai-Thinker documents the Rd-03D on the S5KM312CL radar SoC, in the 24 GHz K band with a maximum swept bandwidth of 0.25 GHz. It describes FMCW operation with proprietary signal processing and an MCU tracking algorithm that reports multi-target speed and range plus motion trajectories. Firmware 2307 is published as the standard multi-target tracking build at V1.0.0, alongside a PC tool, a serial flashing tool, a quick-start guide, a user manual, power and reliability test reports, and a fixed-frequency test guide. Its comparison table loads dynamically, so no static electrical figures were available on the documentation page.

Item LD2450 Rd-03D
Band 24 to 24.25 GHz 24 GHz K band
Antenna 1T2R Not stated on the static page
Published range 6 m No static figure
Resolution 0.75 m Not stated
Max targets 3 moving targets Multi-target with trajectories
UART default 256000 baud Documented serial protocol, rate per manual
Firmware path BLE and OTA, PC tool Published image 2307 V1.0.0

Coordinates are relative, and the count is a ceiling

Neither module gives room coordinates. The LD2450 x and y values are relative to the sensor face, and the tracker reports moving targets rather than a census of everyone in the room. A stationary person is not reliably reported as a new moving target, so an application that needs presence as well as position should use a separate presence channel or a module that reports still targets.

Three is a ceiling, not a target guarantee. Targets can merge when they are close together, and the 0.75 m resolution is a vendor figure for separating range, not a promise of sub-metre tracking. Treat the count as an upper bound in the data contract with the host.

Use zones to remove regions, not to add accuracy

ESPHome supports up to three zones on the LD2450, including an exclude mode that removes an area from detection. Zones are useful for masking a doorway, a fan or a pet path so the tracker stops spending its target budget on motion you do not care about. They do not improve the underlying resolution, and a zone boundary is not a geometric wall in the sensing field.

Mount at the height the vendor documents. Hi-Link suggests 1.5 to 2 m for wall mounting the LD2450. Confirm the tracking output at that height before moving the board, because a change in mounting angle moves every coordinate in the stream.

Keep the parser tied to the firmware

Fetch frame structure, length fields, payload order and checksum rules from the protocol document for the exact firmware you flashed. Hi-Link publishes an OTA path and a PC tool; Ai-Thinker publishes a firmware image and a serial protocol. A frame parser written against one of these modules will not transfer to the other even when both sit in the 24 GHz band.

Archive the firmware version, protocol revision, tool version and part marking next to the parser. Re-run the frame and coordinate checks after any firmware change.

No physical module was bench tested for this chapter. All figures above are documented values from the linked sources and must be confirmed on the bench before they are used as a measurement.