A stepper motor aims an mmWave FMCW radar to keep walking heart rates in view
Non-contact heart-rate sensing with radar has gotten accurate, but almost every method quietly assumes the person sits still. A 2024 paper in IEICE Transactions on Communications takes a blunt mechanical route around that assumption: when the subject walks, the radar moves too. It mounts a 77 to 81 GHz FMCW radar on a stepper motor and aims the beam at the person using the radar's own angle estimates, with no camera and no second unit to triangulate from.
Why the person has to stay still
The motivation is a real one. Cardiovascular disease accounts for 25.5 percent of deaths in Japan, and night-time monitoring of people living alone or in nursing homes is an unsolved need. Wearable electrodes and bands are poor for continuous 24-hour wear and unfriendly to fragile skin, so contactless radar monitoring has drawn steady attention.
Three radar families each fall short in a different way. IR-UWB radar is power-limited and pays in signal-to-noise ratio and accuracy. Continuous-wave Doppler radar has no range resolution and is easy to disturb. FMCW mmWave radar measures both range and velocity and is sensitive enough to the tiny chest displacement of a heartbeat, which is why it became the mainstream choice, and the paper uses a 77 to 81 GHz part. The catch is that nearly all studies require the subject to be seated, standing or lying still, and the radar module's own field of view is narrow: widen the beam with beamforming and the gain drops. Placing several radars to cover a room means mutual interference, higher noise floor and higher cost.
Prior attempts to handle motion also had sharp edges. Mounting the radar on a mobile robot creates a trip hazard from the power cable and cannot monitor while charging. Aiming the radar with a camera inherits the camera's light dependence and raises privacy questions in bedrooms and care facilities, exactly where monitoring matters most.
The idea: the radar finds the person, then turns
The core loop is one sentence: use radar signal processing to compute where the person is, send the angle to a stepper motor, and keep the radar pointed at them. The authors chose a stepper over a servo for three practical reasons: it is brushless and therefore more reliable, its position error does not accumulate, and it is cheap and simple because it only responds to digital pulses. The hardware is a TI IWR1443 module running 1Tx4Rx in SIMO mode, a NEMA17 stepper motor, an Arduino UNO for serial bridging, and a circular turntable, with the radar constrained to a 3.6 GHz sweep bandwidth by Japanese radio law. The four receive channels are what give it angle.
One trade-off is worth flagging: the design deliberately stays in SIMO rather than MIMO. MIMO would lengthen the frame period and add compute, slowing the motor enough that the person could leave the beam, and at a fixed frame period it would shorten the single-channel data used for chest displacement and hurt the intermediate-frequency phase quality. For heart-rate work, phase quality matters more than angular resolution, and that priority runs through the whole paper.
The processing chain: decide every 0.2 seconds whether to turn
The pipeline splits into two lines, one for heart rate and one for motor control. The radar runs a 0.05 second frame period with L chirps per frame, chosen because a heartbeat is under 2 Hz and a 20 Hz effective sample rate satisfies the sampling theorem, while a shorter frame would flood the link with packets. Each frame gets a range FFT into a range-profile matrix, then a slow-time Doppler FFT into a range-Doppler matrix.
The motor line works in four steps. First it runs 2D-CA-CFAR detection on the range-Doppler matrix and keeps points above threshold; the authors picked CA-CFAR over the stronger OS-CFAR because the scene is simple, usually one person, and real-time matters. Second it estimates instantaneous velocity from Doppler and arrival angle from the four-channel phase difference, building a candidate matrix of range, velocity, angle and absolute x, y. Third it picks the target to track by assuming near-constant velocity and drawing a small search circle around the last locked position, about 0.2 meters at a 0.2 second period and 1 meter per second, so only candidates inside count. Fourth the motor acts only every M equals 4 frames, or 0.2 seconds, and only if the person is more than 5 degrees off axis, which avoids jitter from tiny corrections. The heart-rate line uses the authors' earlier improved adaptive range-bin selection followed by ICEEMDAN decomposition, pulling out the component concentrated at 0.8 to 2.0 Hz to rebuild the heartbeat.
The experiment: five fixed routes, random walk, arm swing, three people
Six volunteers took part, with the radar height set to each person's chest and an ECG device worn as ground truth, 60 seconds per measurement alternating walking and standing. Five fixed routes covered three straight lines at 0.5, 1 and 1.5 meters at 90 degrees to the radar, a 180 degree arc of 1 meter radius, and a 4 by 2 meter rectangle, the first four each at 0.5 and 1 meter per second, then a free random walk inside a 4.5 by 5 meter area. An arm-swing comparison answered whether normal walking arm motion interferes, and a three-person scene had the target walk back and forth 0.5 to 3.5 meters while two others moved randomly at 1 and 3 meters.
Results: tracks well, measures accurately
Tracking held up: the measured angle of arrival stayed within plus or minus 35 degrees of straight ahead across all trials, and 90 percent of the straight-line angle errors were under 10 degrees, including on the 180 degree arc, which led the authors to suggest that a radar at a room's center could in principle give 360 degree coverage. On heart rate, fixed routes came in under 2.85 bpm root-mean-square error at 0.5 meter per second and under 4.05 bpm at 1 meter per second; the random route stayed under 6.85 bpm with a 4.35 bpm average. Overall accuracy exceeded 96 percent and reached 98.42 percent on the best route, 80 percent of points landed within 2.9 bpm, and none exceeded 6 bpm. The rebuilt beat's RR interval correlated with the ECG reference at 0.9905.
Arm swing did cost 0.3 to 0.56 percent in accuracy because the moving arm perturbs the chest-phase signal, but the effect was small. The three-person scene still averaged 96.22 percent, since the velocity-extrapolation in the range-bin selection survives brief overlap in the range profile. Against prior stationary work at 1 to 2.5 meters with RMSE around 2.39 to 4.69 bpm, this approach measured a walking person up to 3.6 meters away at 3.67 bpm.
What it still needs
The most practical limit is latency. ICEEMDAN needs a long window, and at a 10 second window the frequency resolution of 0.1 Hz was unstable, so the experiments used a 30 second window with a 1 second slide, meaning the reported rate is effectively a half-minute average and reacts slowly to sudden changes. The mechanical scheme also carries its own noise: motor vibration pollutes the phase data, and the authors list a quieter platform as the next step. Accuracy drops when the person stands sideways to the radar, and the six-subject sample is small with no direct comparison to a like-for-like scheme, since the paper claims to be the first to aim a radar with a motor for heart-rate tracking.
Why it matters for builders
The point that travels beyond the paper is not a clever algorithm but a judgment most researchers skip: when signal processing has been pushed to ICEEMDAN, the real bottleneck may be that the radar is not aimed at the person. A few-dollar stepper motor moves mmWave heart-rate monitoring from a lab bench where the subject sits upright to a room where they walk around, while keeping error near 4 bpm, which for elderly monitoring may beat another 0.1 percent of algorithm gain. The 30 second window delay and the motor vibration are the two things that have to be solved before this becomes a product rather than a demonstration.
The paper is A Novel Remote-Tracking Heart Rate Measurement Method Based on Stepping Motor and mm-Wave FMCW Radar, IEICE Transactions on Communications, Vol.E107-B, No.6, pp.470-486, 2024, DOI 10.23919/transcom.2023EBP3143.
This article is part of the mmWave Radar channel.