Presence and distance-gate radar: the LD2410 type
A handbook for static-presence radar modules that report per-gate motion and stillness, based on LD2410-AA and ESPHome documentation.
Presence sensors of this type answer two questions: is anyone there, and roughly how far away. They do not give room coordinates. The useful integration data is per-gate energy and a configurable no-person delay, so this chapter focuses on how to read and tune those two things.
Identify the exact variant before the electrical row
The LD2410 family name covers more than one board. The official page describes the LD2410-AA with a 24.01–24.18 GHz FMCW front end, one transmit and one receive antenna, and a maximum swept bandwidth of 0.17 GHz. The directory also lists the LD2410D-B as a separate part. Supply voltage, pinout and default firmware can differ between variants, so copy the electrical row from the datasheet of the board you actually ordered.
Hi-Link publishes the AA module at 4.5 to 5.5 V, typically 5 V, with 80 mA average current. Serial is 3.3 V TTL. On the AA page the default UART rate is 115200 with one stop bit and no parity, and the refresh period is 100 ms, or 200 ms at 9600 baud.
One source conflict is worth recording rather than smoothing over. The ESPHome LD2410 component text quotes a 256000 baud rate as the sensor default, while the Hi-Link AA product page states 115200. Treat the two as applying to different variants or firmware, and confirm against the protocol document for your board before fixing the host baud rate.
Read gates, not a single threshold
A distance gate is a slice of range. The AA page lets you configure sensing distance, a threshold for each gate, and a no-person delay. Trigger and hold are configured separately, which is what lets a presence output stay stable when a person sits still.
The ESPHome component exposes this as binary sensors for a moving target and a still target. In engineering mode it also publishes per-gate moving energy and still energy from gate 0 upward, plus moving distance, still distance and detection distance. The basic report gives the presence decision; the engineering report gives the evidence behind it. If the host only needs a room-occupied flag, the basic report is enough. If it needs to know which part of the room caused a trigger, engineering mode is the contract to enable first.
| Question | Report to use |
|---|---|
| Is anyone present | Presence binary sensor from the basic report |
| Moving or still | Moving and still target binary sensors |
| Which gate caused the trigger | Per-gate moving and still energy in engineering mode |
| Where the detection sits in range | Moving distance, still distance, detection distance |
Tune in this order
Range, per-gate threshold and no-person delay are three separate controls. Changing one does not retune the others. A practical order is to set the physical mounting first, then the outer range, then the per-gate thresholds from the engineering energy values, and only then the no-person delay that decides how long presence persists after the signal disappears.
The AA page lists wall and ceiling figures that differ by several metres. It quotes 9 m for motion and 6 m for a seated person in wall mounting, 6 m and 4.5 m at a 3 m ceiling height, and 6 m and 4 m at a 6 m ceiling height, all at a 60 degree detection angle. These are vendor-published figures for a given installation, not a guaranteed envelope for every room. Walk the boundary and read the gates before treating any of them as your range.
Hi-Link also documents a BLE configuration path through its app and a PC tool with live radar data, so a first baseline can be captured without writing a parser. The page names a default app password; change it and record the final setting in the project log.
Write down what you validated
Keep the variant part number, firmware version, UART rate, gate thresholds, no-person delay and mounting geometry together. A reflash or a change of enclosure is a realistic event, and the same gate layout will read differently after either. Re-capture the engineering energy values after every such change instead of reusing an earlier baseline.
No physical module was bench tested for this chapter. All figures above are documented values from the linked sources and must be confirmed on the bench before they are used as a measurement.