How to choose a harmonic reducer: series, frame size, ratio and backlash
Match the series to the joint, the frame to the torque, and the ratio to the speed the axis actually needs.
This guide is compiled from the manufacturer's published documentation. We have not measured these parts on a test bench.
Start from the joint, not from the part
A harmonic reducer is chosen by the hole it has to fill. Four questions decide most of the answer before any parameter table is opened.
- Where does the output flange sit, and how much axial space is there behind it.
- Does anything have to pass through the joint centre: cables, pneumatics, a gas line, a laser beam.
- What peak torque appears at the output flange during the worst normal move, not the average move.
- What output speed does the axis reach, because that sets the input speed once the ratio is fixed.
Only after those four are answered does the frame and ratio selection become arithmetic.
The reducer series side by side
Leaderdrive publishes several reducer families that share one working principle and differ in output geometry.
| Series | Flexspline shape | Frames | Ratios | Rated torque | Typical use |
|---|---|---|---|---|---|
| LCS | Cup-shaped, standard | 14 to 58 | 30:1 to 160:1 | 4 to 745 N·m | General robot joints and servo axes |
| LCSG | Cup-shaped, high torque | 14 to 58 | 50:1 to 160:1 | 7 to 969 N·m | The same joints with a heavier payload |
| LHS | Hat-type, hollow flange | 14 to 58 | 30:1 to 160:1 | 4 to 176 N·m | Wrists that route cabling through the centre |
| LHSG | Hat-type, high torque | 14 to 58 | 50:1 to 160:1 | 7 to 969 N·m | Heavier wrists and rotary axes |
| LCD | Cup-shaped, ultra-flat | 14 to 40 | 50:1 to 160:1 | 3.7 to 206 N·m | End joints with almost no axial room |
| LHD | Hollow shaft, ultra-flat | 14 to 40 | 50:1 to 160:1 | 3.7 to 206 N·m | The flattest stack that still needs a bore |
| LCS-Mini | Cup-shaped, miniature | 3 to 11 | 50:1 and 100:1 | 0.11 to 5 N·m | Fingers and miniature end effectors |
Explore the series pages for the full parameter tables.
- Explore Leaderdrive LCS / LCSG strain wave gears
- Explore Leaderdrive LHS / LHSG strain wave gears
- Explore Leaderdrive LCD ultra-flat strain wave gears
- Explore Leaderdrive LHD ultra-flat hollow-shaft gears
- Explore Leaderdrive LCS-Mini strain wave gears
Frame size is the torque axis
Frame size is the primary scaling dimension. A larger frame carries more torque at the same ratio, and it usually adds higher ratios to the list for that frame.
Two consequences follow, and both are easy to get wrong.
- The rated torque of a series is a span across its frames, not a value that applies to the part that arrives. A frame 14 unit and a frame 58 unit are in the same series and differ by more than an order of magnitude in torque.
- A ratio that exists on a large frame may not exist on a small one. In the LCS family the smallest frames stop at 100:1, and 160:1 starts at frame 20.
The usable rule is to pick the ratio first, because that is driven by the axis speed, then pick the smallest frame that carries the torque at that ratio. Going up a frame to gain stiffness is legitimate, but it costs mass and bolt-circle diameter at the joint.
Choosing the reduction ratio
A single harmonic stage gives a large reduction, which is the reason it is used at a joint rather than a gear train.
- A higher ratio multiplies input torque more and reduces output speed for the same input speed.
- Ratios are not continuous. The catalogue lists discrete values such as 30:1, 50:1, 80:1, 100:1, 120:1 and 160:1.
- Peak torque at start and stop is a separate rating from rated torque, and it is the one that matters during emergency stops and reversals.
Rated torque is quoted at the rated input speed of the model. Running the same unit faster raises the input speed without changing the quoted rating, so a margin on torque is the normal way to absorb a faster duty cycle.
Standard or high-torque
The high-torque variants, LCSG and LHSG, use high-rigidity roller bearings and a strengthened design. The published torque carrying capacity is about 30 percent higher than the standard version at the same frame.
Choose the high-torque version when the frame size is fixed by the joint geometry and the payload keeps pushing against the standard rating. Choose the standard version when there is room to step up one frame instead, because a larger standard unit is often the cheaper answer.
Accuracy and backlash
These are the two numbers most often confused, and they describe different things.
- Backlash, quoted as a maximum in arcsec, is the lost motion when the output is reversed. Series such as LCS, LCSG, LHS, LHSG, LCD and LHD are published with a maximum backlash of ≤10 arcsec.
- Transmission accuracy, quoted in arc-min or arcsec, is how far the actual output angle can differ from the commanded angle over a full turn.
Backlash below 10 arcsec is what makes a harmonic stage suitable for a position-controlled joint without a secondary encoder at the output. It does not by itself guarantee repeatability, because stiffness, thermal drift and the control loop all contribute. The manufacturer publishes torsional rigidity and hysteresis figures per frame, and those are worth reading before a high-dynamic axis is designed around the reducer.
The third-harmonic option
Leaderdrive also publishes the Model Y series, which uses a third-harmonic tooth profile rather than the conventional two-lobe engagement. The reason to look at it is accuracy under vibration: the series is published as reaching transmission accuracy within 10 arcseconds. It covers frames 17 to 40 at ratios from 80:1 to 160:1, which is a narrower catalogue than the standard families, so it is a targeted choice rather than a default.
Ordering details that change the part number
Two choice points are easy to leave until late and expensive to change afterwards.
- Component set or unit type. A component set is the flexspline, circular spline, wave generator and bearing as separate parts; a unit type is assembled with a cross roller bearing that carries the external load directly. The two are separate order lines.
- Input coupling. The standard cup series is offered in an I version that matches the input shaft to the wave generator bore with a flat key, and a II version that uses an Oldham coupling to absorb misalignment. The hat-type series adds hollow-shaft and solid-shaft input variants.
Neither form includes the motor, the encoder or the brake. Those are specified separately whatever the joint architecture is.
Confirm before ordering
- The series, by output geometry and whether a through-bore is required.
- The frame size that carries the peak torque at the chosen ratio.
- The exact ratio, checked against the row for that frame rather than against the series envelope.
- The input coupling variant and whether a component set or a unit type is wanted.
- The flange bolt pattern, pilot diameter and the mounting drawing for that frame.
- The torsional rigidity and hysteresis figures if the axis will run fast or reverse often.
What this guide cannot tell you
We have not measured backlash, torsional rigidity, efficiency, service life or noise on any of these units. The figures above are the manufacturer's published values. Real performance depends on the mounting surface, the alignment of the input, the lubrication, the load spectrum and the control loop, and those live in the machine rather than in the catalogue.
Official reading
- Leaderdrive LCS / LCSG standard cup-shaped strain wave gear
- Leaderdrive LHS / LHSG standard hat-type strain wave gear
- Leaderdrive LCD ultra-flat cup-shaped strain wave gear
- Leaderdrive LHD ultra-flat hollow-shaft strain wave gear
- Leaderdrive LCS-Mini cup-shaped strain wave gears
- Leaderdrive Model Y third-harmonic strain wave gear