Harmonic Reducers
LHD Ultra-Flat Hollow-Shaft Gears
Ultra-flat hollow-shaft strain wave gears that combine the flattest possible stack with a through-bore for wiring.
Capabilities below are vendor-documented. We have not tested this device or its integrations.
Sources checked:
Also known as: LHD harmonic reducer, LHD ultra-flat hollow-shaft, 绿的谐波 LHD 系列
Suitable projects
- The flattest joint stack that still needs a hollow bore.
- Robot wrist modules with wiring or pneumatics routed through the reducer.
- Space-critical assemblies where axial height and weight both matter.
Before you buy
- Frame range stops at 40; larger joints need the LHS or LCS series.
- Bore and mounting-flatness tolerances are tight, so follow the official installation drawing.
- Not the series to choose when torsional stiffness is the priority.
Official resources
Related guides
- Frame sizes
- 14 / 17 / 20 / 25 / 32 / 40
- Reduction ratios
- 50:1 to 160:1
- Rated torque
- 3.7 to 206 N·m
- Peak torque at start/stop
- 12 to 453 N·m
- Max backlash
- ≤10 arcsec
- Max input speed
- up to 8500 r/min
- Flexspline
- Ultra-thin hollow flanged shape
Choosing Leaderdrive LHD Ultra-Flat Hollow-Shaft Gears
This profile is based on official documentation, not our own device testing.
What this series is for
The LHD series is an ultra-flat strain wave gear with an ultra-thin hollow flanged flexspline and a through-bore. It is a unit type, so the reducer and its housing arrive as one part.
The series suits the flattest joint stack that still needs a hollow centre. Robot wrist modules route wiring or pneumatics straight through the reducer, and space-critical assemblies use the same geometry where axial height and weight both matter.
The difference from the LCD series
Inside the same frame range, the LHD and the LCD carry the same rated and peak torque figures. The frame sizes are identical, and the ratios, backlash and input speed limits are shared.
So torque is not the decision. The decision is output geometry. The LCD finishes in a flange, while the LHD leaves a bore through the centre of the axis.
If the cabling has to pass through the joint, that bore is the reason to pick the LHD. If it does not, the LCD is the simpler part and the extra bore is wasted design work.
Frame sizes and torque
The series covers frames 14, 17, 20, 25, 32 and 40.
The official table prints a single ratio column for these frames. The values below are the 50:1 rows, and they match the LCD series frame for frame.
| Frame | Ratio in this table | Rated torque (N·m) | Peak torque at start/stop (N·m) |
|---|---|---|---|
| 14 | 50:1 | 3.7 | 12 |
| 17 | 50:1 | 11 | 23 |
| 20 | 50:1 | 17 | 39 |
| 25 | 50:1 | 27 | 69 |
| 32 | 50:1 | 53 | 151 |
| 40 | 50:1 | 96 | 281 |
The through-bore is the real decision
The bore diameter is not the same for every frame. Read the bore size for the chosen frame from the official mounting drawing, and check that the connector, cable bundle or tube that has to pass through it fits with clearance.
The bore also sets the wiring plan. A hollow-shaft joint routes the cable inside the centre of rotation, so the bend radius and the strain relief move into the joint design. Confirm both against the official installation drawing.
Bore and mounting-flatness tolerances are tight on this series. Follow the official installation drawing rather than general workshop practice.
How frame size maps to torque
Each step up in frame size raises the torque capacity. Going from frame 14 to frame 40 at 50:1 moves rated torque from 3.7 N·m to 96 N·m, and peak torque at start/stop from 12 N·m to 281 N·m.
Choose the smallest frame that carries the rated torque of the joint, then check the peak torque at start/stop for the acceleration and deceleration phases. Check the bore for that same frame at the same time, because the torque requirement and the bore clearance can pull the choice in different directions.
Picking a ratio
Reduction ratios in the series run from 50:1 to 160:1. The official table prints the 50:1 column for these frames, and the higher ratios carry the rest of the torque envelope.
The series envelope reaches 206 N·m rated torque and 453 N·m peak torque at start/stop, both above the frame 40 row at 50:1. Maximum backlash is ≤10 arcsec and maximum input speed is up to 8500 r/min for the series, so confirm both against the exact model.
Frames above 40
The frame range stops at 40. A larger joint needs the LHS hollow-shaft series or the LCS cup series, which extend the frame range further.
Check before ordering
Confirm the bore. Read the bore size for the chosen frame from the official drawing, and check that the cable, connector or tube passes through with clearance.
Confirm the frame and ratio. The torque figures are shared with the LCD, so the reason to order the LHD is the bore, not a torque advantage.
Check the stiffness figures. Torsional stiffness is the trade-off on an ultra-thin flexspline. This is not the series to choose when stiffness is the priority, so check the figures for the exact model in the official parameter table.
Confirm the mounting tolerances. Bore and mounting-flatness tolerances are tight. Copy the drawing tolerances into the mechanical design before ordering.
Next step
Open the official Leaderdrive LHD product page on leaderdrive.com, read the parameter table and the mounting drawing for the chosen frame, and confirm the bore clearance before placing the order.
Quick Start — Leaderdrive LHD Ultra-Flat Hollow-Shaft Gears
Reference steps for mounting the hollow-shaft unit on the bench. They follow the official installation drawing, so confirm every tolerance and torque value against that drawing for the exact model.
1. Check what arrived
The unit ships assembled, as a complete reduction stage with a bore through the centre. Confirm the part number on the label against the order before opening anything else.
Check the packing list for fasteners, the input coupling and lubricant. Treat anything that is not on the list as not supplied.
Inspect the bore, the flange faces and the flexspline for dents or shipping damage. A burr raised inside the bore is hard to remove once the joint is closed.
2. Prepare the mounting surfaces
Flatness and coaxiality on the mating surfaces drive the life of the reducer, and the hollow shaft adds a second alignment job on the bore axis. Read the tolerances from the official installation drawing and measure the surfaces before assembly.
A surface that is not flat pulls the housing out of shape when the bolts are tightened, and that load lands on the flexspline and the wave generator bearing.
Clean both mating faces and the bore. Burrs, paint and chips all count as flatness error, and swarf left in the bore will ride on the cable.
3. Tighten the flange bolts
Tighten in a crosswise sequence, working around the bolt circle in stages rather than taking each bolt to full torque in one pass.
Use the torque figure from the official installation drawing and the bolt grade it specifies. Confirm the thread and the bolt length that the flange uses rather than assuming them.
Re-check the runout of the output flange once the bolts are at final torque. Bore runout matters on this series because the cable passes through the rotating centre.
4. Lubricate
Use the lubricant the official instructions specify for the model, and apply the quantity they state. Do not mix two different greases in one unit.
The surfaces that matter are the flexspline and circular spline teeth and the wave generator bearing. Keep lubricant out of the cable path unless the drawing says otherwise, and add lubricant before the first run.
5. Couple the input to the servo or stepper
The servo or stepper drives the wave generator input. Keep the input aligned with the motor shaft, and use a coupling that tolerates the small misalignment the drawing allows.
Do not hang radial or axial load on the input. Belt tension, a heavy pulley or a rigidly bolted hub all load the input bearing in a way it was not designed for.
Route the cable through the bore before closing the joint, with the bend radius and the strain relief the official drawing specifies.
Respect the input speed limit for the model, up to 8500 r/min for the series. Run a short low-speed check before the first full-speed move, and watch the cable for rub marks.
6. Check backlash after assembly
Measure backlash at the output with the input held, using the method in the official instructions. Compare the result with the ≤10 arcsec maximum in the specification.
Backlash is set by the reducer, so a large reading usually points at mounting distortion rather than a faulty unit. Check the mounting surfaces and the bolt torque before blaming the gear.
7. Mistakes that ruin a reducer
- Mounting on a surface that is not flat, so the housing distorts under the bolts.
- Overtightening the flange bolts, or tightening in a circle instead of crosswise.
- Running the unit dry, or with the wrong lubricant, or with two greases mixed.
- Loading the input with belt tension, a heavy pulley or a rigid hub.
- Running the cable tight through the bore, with no bend radius or strain relief.
- Leaving swarf inside the bore, so it grinds against the cable.
- Using the peak torque at start/stop as a continuous rating.
- Forcing a misaligned joint together instead of re-machining the mating part.
Next step
Follow the official installation drawing and parameter table for the exact model. Record the measured backlash, the bolt torque used and the cable routing, so the next service has a baseline.
FAQ — Leaderdrive LHD Ultra-Flat Hollow-Shaft Gears
What is the difference between the LHD and the LCD series?
Both are ultra-flat strain wave gears in the same frame range, and the official tables give them the same rated and peak torque figures. The LCD ends in a flange, while the LHD carries an ultra-thin hollow flanged flexspline and leaves a bore through the axis. The decision is output geometry, not torque.
Why choose the LHD over the LCD?
Order the LHD when wiring or pneumatics has to pass through the centre of rotation, or when the joint needs the flattest possible stack with a hollow centre. If nothing passes through the axis, the LCD does the same job with a simpler output.
Which frame sizes does the LHD series cover?
The series covers frames 14, 17, 20, 25, 32 and 40. Larger joints need the LHS or LCS series.
How big is the through-bore?
The bore size is set per frame and is given in the official mounting drawing. Read the figure for the chosen frame there, and check that the connector, cable bundle or tube passes through with clearance.
How much torque can an LHD frame carry?
At 50:1 the rated torque runs from 3.7 N·m at frame 14 to 96 N·m at frame 40. Peak torque at start/stop runs from 12 N·m to 281 N·m over the same frames, and the series envelope reaches 206 N·m rated and 453 N·m peak at start/stop.
What ratios are available in the series?
Reduction ratios run from 50:1 to 160:1. The official table prints the 50:1 column for the frames in this series, so the other ratios have to be read from the full parameter table.
What is the maximum backlash and input speed?
Maximum backlash is ≤10 arcsec and maximum input speed is up to 8500 r/min for the series. Confirm both figures for the exact model before ordering.
Is the LHD suited to every flat joint?
No. Torsional stiffness is the trade-off on an ultra-thin flexspline, so this is not the series to choose when stiffness is the priority. Bore and mounting-flatness tolerances are also tight, so the official installation drawing governs the assembly.
Can the LHD series be ordered above frame 40?
No. The frame range stops at 40. A larger joint moves to the LHS hollow-shaft series or the LCS cup series.