Integrated joint or separate parts? Choosing a robot actuator architecture

An integrated actuator trades control freedom for assembly time. A reducer plus your own motor trades assembly work for control over the drive.

This guide is compiled from the manufacturer's published documentation. We have not built or measured either architecture.

Two ways to build the same joint

Almost every robot joint performs the same three jobs: convert electrical power into torque, reduce the speed to something the link can use, and report the output angle. The architectures differ only in who does the packaging.

Neither is better in the abstract. The decision follows from how many joints you are building and how much of the motion behaviour you intend to own.

The comparison

Question Integrated actuator Separate parts
What arrives One sealed unit with motor Reducer, motor, encoder, drive purchased separately
Motor type Fixed by the maker Yours to choose
Control loop Yours, but constrained by the supplied motor Fully yours, including field-oriented control settings
Backlash Set and sealed at the factory Set by your own assembly
Cabling inside the joint Routed through the hollow bore Depends on your mechanical design
Sealing Sealed unit, rated IP Your enclosure decides the rating
Service access Replace the unit Replace one component
Engineering effort Mechanical mounting only Mechanical plus drive tuning
Best when Few joints, or rapid prototyping Many joints, or a control requirement to meet

When the integrated actuator wins

The Leaderdrive KAH series is an example of this architecture. It combines a strain wave reducer with a magnetic stepper motor in a sealed hollow-shaft body.

The case for it is shortest when the joint count is small, when the schedule matters more than the drive tuning, or when the machine is a prototype whose dimensions will change. Mechanical design effort drops to a mounting flange and a bore routing decision.

When separate parts win

A bare reducer plus a motor of your own is the usual choice once the design is frozen and the joint count starts to climb.

The cost is entirely in engineering hours: alignment, backlash setting and drive tuning all become your responsibility.

Where the reducer sits in both cases

Both architectures end at a harmonic reducer, and the reducer choice is made the same way either way. The output geometry, the frame size and the ratio are decided by the joint, not by the architecture.

The selection logic for the reducer itself is covered separately.

What to specify either way

What this guide cannot tell you

We have not compared real joints on a dynamometer, and we have not measured backlash drift, thermal behaviour or efficiency in either architecture. We also have not verified the electrical interface of the integrated actuator: the manufacturer's public material does not publish its connector, bus or command set, so those have to be obtained from the supplier before wiring anything. Nothing here is a substitute for a test on the actual duty cycle.

Official reading