What Zigbee2MQTT really exposes for radar sensors

Zigbee2MQTT publishes a fixed set of attributes, and for a radar occupancy sensor that set is far smaller than the radar data itself. The bridge does not forward clusters; it forwards whatever the device converter in the bridge defines as exposes.

This guide uses the official Zigbee2MQTT device page for the SONOFF SNZB-06P and the official component documentation for the LD2410 and LD2450 modules. It is not a bench test.

The four exposes on the SNZB-06P page

The official page lists exactly four:

Expose Type Direction Range or values
occupancy binary read true or false
occupancy_timeout numeric read and write 15 to 65535
occupancy_sensitivity enum read and write low, medium, high
illumination enum read only dim, bright

Two details matter more than the list.

The sensitivity expose is a three-step enum, not a number. Any metre figure for those steps that appears in a vendor app or a shop page is not part of the bridge contract; the bridge only guarantees that three named levels can be selected.

Illumination is updated when occupancy is detected, not on a schedule. It is a dim or bright category, not a lux reading, so it cannot drive a light-level automation that expects a measurement.

The timeout is the device-side hold time: after motion stops, occupancy stays true for that many seconds before clearing. It is not a freshness timer for the bridge.

Timeout is not availability

These two numbers are routinely confused, and the confusion produces false alarms in both directions.

The documented defaults are 10 minutes for an active device and 1500 minutes, about 25 hours, for a passive one, and the timeout persists across bridge restarts. Per-device overrides exist, so one sensor can be given a shorter threshold without changing the whole network.

That is why a value that has not changed for an hour proves nothing: occupancy false is a legitimate state, and old data is not the same as a dead device.

What is missing from the list, and why

There is no distance gate, no per-gate energy, no target coordinate, no zone and no point cloud. Four reasons:

  1. The device is a finished Zigbee product with a small cluster set, not a radar development board.
  2. The bridge only exposes clusters that its converter handles.
  3. The SNZB-06P uses 5.8 GHz microwave sensing, which is not mmWave radar; the signal chain that would produce gates is not the one in an L2 module.
  4. Gate-level data has no standard Zigbee cluster to travel in, so even a device that computed it would need a vendor-specific attribute.

Comparing three depths of exposure

Device and path Presence Distance or gates Coordinates Notes
SNZB-06P over Zigbee2MQTT occupancy, timeout, sensitivity none none Room-level trigger, four exposes
LD2410 over ESPHome moving, still, either target moving, still and detection distance; per-gate energy in engineering mode none Also exposes per-gate thresholds, max distance gates and a light threshold
LD2450 over ESPHome presence plus target counts distance per target X and Y per target, up to three targets, plus per-zone counts Needs a recent module firmware

The comparison explains a common disappointment: a user buys a finished Zigbee sensor, then discovers that the automation they designed needs gate energy. The sensor is not faulty, the output class is different.

Getting gate data into MQTT anyway

If the automation genuinely needs gates or coordinates, the path changes rather than the bridge:

A vendor gateway can also expose a subset of radar data, but treat its feature list the same way: only what the gateway publishes is usable, and a vendor app screen is not a published interface.

A check that takes two minutes

  1. Open the exact device page on the Zigbee2MQTT site and read the exposes list.
  2. Write down the attribute your automation needs.
  3. Publish a get request to the device topic with that property name.
  4. If the reply does not contain it, the bridge will not publish it, whatever the vendor app shows.