Two radars in one home: coexistence without invented spacing numbers
Vendors list nearby radars as an interference source but publish no minimum spacing. Here is a test-led way to plan a second sensor.
What the vendors actually publish
The installation notes name the problem without quantifying it. Seeed lists multiple radars installed too close together for the MR60FDA2, alongside glass, thin wooden boards and vibrating mounting locations. Hi-Link lists multiple radars close together for the LD2450, alongside thin walls and metal reflections. The MR60BHA2 page adds nearby radars to its list of conditions that affect the reading.
None of those pages gives a separation distance, an isolation figure or a channel plan. That is the honest starting point: co-location is a documented interference source, but the acceptable distance depends on the room, the mounting angle, the output type and the firmware thresholds. A rule such as "keep them two metres apart" would be invented.
Bands are not a channel plan
The directory spans several bands. The LD2410, LD2450 and Rd-03D are 24 GHz modules. The C1001 and the MR60 kits are 60 GHz devices. The SNZB-06P is a 5.8 GHz microwave sensor.
Using different bands reduces the chance that two sensors share the same front-end passband, but it is not a guarantee. A 24 GHz and a 60 GHz sensor do not become invisible to each other; they simply stop competing for the same frequency range. The module pages in this directory do not document a channel-selection setting, so there is no firmware knob to move one sensor onto a different channel.
Separate the fields of view first
Physical planning is more effective than firmware tuning. If two sensors serve two rooms, mount them so their main beams point away from each other and avoid overlapping coverage. A back-to-back mount reduces the shared field of view, but reflections from the same wall or doorway can still reach both sensors.
Use the module's own boundary controls to exclude the other room. The LD2450 has three rectangles and a Detection or Filter mode. The LD6002B has detection areas and interference areas that are stored in the module and survive a power cycle. The LD2410 has a maximum gate for motion and stillness. These controls can mask a known region, but they cannot remove interference that arrives inside the intended region.
One host, two instances
Running two sensors from one ESP32 is a bus and identity problem before it is an RF problem. The ESPHome AT581x component documents multiple instances on an I2C bus with addresses 0x28 and 0x29, and requires an id for each instance. The LD2450 component accepts ld2450_id when multiple components are used, and the UART must be configured separately.
Unique IDs and separate ports keep the data streams from colliding. They do not stop the two radars from illuminating each other. The AT581x also documents that its settings are not stored in non-volatile memory and must be applied again on each boot, so a restart can silently return a sensor to different sensitivity settings.
Test one, then both
A coexistence test needs a baseline for each sensor alone before the pair is judged.
| Case | What to record | What would count as a pass |
|---|---|---|
| Sensor A only, B powered off | False triggers with the room empty | A stable baseline you can compare against |
| Sensor B only, A powered off | False triggers with the room empty | A stable baseline for B |
| Both on, different rooms | New triggers in either room | No increase over the two baselines |
| Both on, person in room A | B's output while A is occupied | B does not report a person in A |
| Both on, sensors swapped | Whether the fault follows the sensor or the position | A fault that follows position points to geometry, not the device |
Run the empty-room cases with the HVAC and fans at their normal setting, because those sources are already on the vendor interference lists. Then repeat with a person sitting still, since a still occupant is the case most likely to expose a marginal threshold.
If both sensors trigger each other, change the physical arrangement or move one sensor to a different band. Firmware zones can hide the symptom, but they cannot remove co-channel energy that arrives inside the detection area.
What not to claim
Do not publish a minimum separation distance that the vendor did not publish. Do not claim that different bands guarantee non-interference. Do not claim frame synchronisation between modules; none of the pages in this directory documents a shared trigger or time base.
No hardware was bench tested for this chapter. The interference lists and component behaviours above are documented; the separation that works in a specific room has to be measured there.