Inside an Omron V400-R2 code reader: an ARM9, two RL78s and a mixed BOM
A fixed-mount code reader is the least glamorous device on a production line and one of the few that has to work at every cycle. It sits beside a conveyor, watches parts arrive, decodes whatever is printed or etched on them and hands the string to a PLC. Omron's V400-R2 is one of the small ones: 41 by 33 by 24 millimetres, 90 grams, IP65, powered from a single 5 volt rail.
A teardown of a returned V400-R2CF65 unit, with a cracked window across the lens, gives a rare look at how such a device is partitioned. Two things stand out. The image engine is a self-contained module with its own processor, its own memory and its own board number. And the parts list inside it is thoroughly international, which the teardown reads as evidence of an American origin that the dates do not support.
What the label commits to
The suffix is the specification. CF65 means a 65 millimetre working distance, the short of the two variants; CF125 puts the same body 125 millimetres out. At 65 millimetres the field of view is about 48 by 31 millimetres.
| Property | Rating | How it appears inside |
|---|---|---|
| Imager | 0.36 megapixel monochrome CMOS | One sensor on the optical board, behind the window |
| Illumination | Two red LEDs at 617 nm, one green aiming LED at 539 nm | LED sites around the lens, red bandpass filter alongside |
| Smallest code | 0.076 mm bar, 0.127 mm two-dimensional | Sets the optics, not the electronics |
| Interface | RS-232C, external trigger, NPN OK/NG outputs | 8-pin mini-DIN on the cable, D-sub 9 at the PLC end |
| Power | 4.5 to 5.5 VDC, 265 mA operating, 70 mA standby | Single rail, no internal switching stage of consequence |
| Environment | IP65, 0 to 45 degrees Celsius | Gasketed window, screwed rear cover, no fan |
Two numbers are worth putting together. Spreading 48 millimetres across a sensor roughly 750 pixels wide gives about 64 micrometres per pixel, while the smallest bar the reader claims is 76 micrometres. That is barely more than one pixel per code module, which only works because decoding fits sub-pixel edges rather than counting whole pixels. It also explains why the window crack matters: a fracture across the lens sits inside the optical path, not in front of a disposable cover.
Two processors that do not overlap
The engine is built around an Atmel AT91SAM9G20B, an ARM926EJ-S core at 400 MHz in a 247-ball thin BGA. It is not there for raw speed. The part carries an ITU-R BT.601 and BT.656 image sensor interface, 32 kilobytes each of instruction and data cache, and an external bus controller for SDRAM and NAND, which is exactly the set of features an imaging front end needs and a general purpose microcontroller does not have.
The main board is run by something much smaller. An R5F1017A from Renesas is an RL78/G13: 16-bit, 32 MHz, 16 kilobytes of flash, 2 kilobytes of RAM, in a 24-pin package 4 millimetres square. It sits in the interface area, next to the RS-232 transceiver, and it owns the serial link, the scan button, the indicator LEDs and the buzzer. The same part number appears a second time on the engine's own board.
That division is the interesting design decision. The 400 MHz core does imaging and decoding, mounted inside a shielded can on the engine board. Everything a line engineer touches, from the button to the OK/NG outputs, hangs off a 16 kilobyte microcontroller that a hobbyist could program. Neither part can do the other's job: the small one has no camera interface and no memory to hold a frame, and the large one has no reason to be in the path of a scan button.
The memory map inside the engine
Four memory and interface parts sit within a few square centimetres of the ARM9.
| Part | What it is | What it does here |
|---|---|---|
| FIDELIX FMS4B32LCH | Korean NAND-based multi-chip package | Engine program and working memory in one package |
| cFeon SL160AL | SPI NOR flash | Boot and engine firmware |
| HYESUNG SMHR32BT5H | Rechargeable coin cell | Holds settings while the line is powered down |
| ICL3232E | RS-232 line driver and receiver | Converts logic levels at the connector |
The pattern is a small NOR device for code that must be readable at power-on and a NAND-based package for everything that follows. Both live inside the engine, which is why the engine can be swapped as a unit. The coin cell does not: it sits on the main board, in the domain of the small microcontroller, which suggests the persistent settings a technician edits belong to that side of the device rather than to the engine.
The transceiver is an Intersil ICL3232E, now a Renesas part, which is unremarkable except that it confirms the whole device speaks nothing but asynchronous serial. There is no Ethernet PHY, no fieldbus controller, no IO-Link. At this vintage the reader is a sensor with a serial port, and integration means wiring it to a PLC input and matching baud rates.
Where the board stack does the work
The main board is small. The engine is not: a metal can covering a lens holder and two rigid boards joined by flex, with the flexible printed circuit exiting from between the board layers rather than from a surface. The optical head is a separate assembly, connected by a 34-way flat cable, with imaging and scanning elements on their own boards and a transparent separator between them. The teardown's observation that the two black boards are in fact one rigid-flex construction is the right reading, and it is the reason the tall shielded module and the flat optical head can share a single assembly.
Rigid-flex costs more per square centimetre than either rigid or flexible board alone. It buys two things here: the imaging plane can be positioned independently of the processor, and the highest-vibration path in the device has no connector pair in it.
The optics are LEDs, not a laser
The teardown describes a red filter that keeps only the laser wavelength. That is wrong, and the manufacturer's own data sheet says so plainly: the illumination is two red LEDs at 617 nanometres and the aiming light is one green LED at 539 nanometres. There is no laser diode anywhere in the V400-R2.
The distinction is not pedantry. A filter matched to a 617 nanometre LED has to pass a broad, warm band and reject the fluorescent and daylight background that a factory floor is full of, with an ambient light rating up to 10,000 lux of fluorescent and 100,000 lux of sunlight. A laser source would allow a far narrower passband and a much brighter spot, and would also bring an eye-safety classification that a red LED illuminator does not. Anyone reading the teardown as a description of a laser scanner would size the optics wrong.
What the parts list does and does not prove
The teardown closes with its own conclusion: because the engine uses an Atmel processor, Korean memory and board numbering that does not look like Omron's, the reader must descend from Microscan, the American code-reading company Omron bought in 2017, and the whole V400-R line came from that acquisition.
The dates do not allow it. Omron announced the V400-R series on 14 March 2008. It announced the Microscan agreement on 30 August 2017, Microscan then being a Spectris subsidiary based in Renton, Washington, and completed the purchase on 2 October 2017. The series is nine years older than the acquisition.
This particular unit is older than the acquisition as well. The ARM9 package is marked 1521, a 2015 date code in week 21, so the reader was built at least two years before Omron owned Microscan. Whatever explains the mixed parts list, it is not that.
What the teardown does establish is more modest and more useful: the engine is a bought-in or at least separately built module. It has its own board number, its own processor, its own memory, its own shielding and its own pair of mounting screws, and it plugs into the main board through a flex tail. Whether Omron designed that module in-house or sourced it cannot be read from photographs, and the safest reading of a Japanese instrument full of American, Korean and Taiwanese silicon is the boring one. Industrial vendors buy the best part for each function, and in 2008 the ARM9 with a camera interface was an obvious choice that happened to come from Atmel.
The acquisition did change Omron's catalogue, but along a different line. Microscan's fixed-mount products arrived as MicroHAWK and the V430 family, sold beside the V400-R2 rather than replacing it.
Why the margin is not in the bill of materials
Strip the reader down and the silicon is cheap and old: a processor introduced around 2008, a pair of 16 kilobyte microcontrollers, a handful of megabytes of flash and RAM, one coin cell. Nothing in that list explains the price of a fixed-mount reader.
The rest of the cost is elsewhere. Reading codes at up to 500 metres per minute, a figure Omron qualifies by code type and print quality, is an algorithm problem, not a component problem. Sealing a window and a rear cover to IP65 is a mechanical problem. Making a device that a maintenance technician can teach with a printed menu sheet, over a serial line, is a documentation and firmware problem. And keeping a 2015 design in production for a decade is a supply commitment that never appears on a parts list but is paid for in every unit.
For an integrator specifying a reader, the teardown is still worth reading, for three checks it makes concrete. Confirm the illumination wavelength and make sure the filter matches it, because an LED and a laser fail differently. Compute pixels per module at your actual working distance before believing a minimum resolution figure. And confirm the interface you have rather than the one you assumed, since this class of device may offer nothing but RS-232C.
How this was checked
Electrical and optical ratings come from Omron's own V400-R2 catalogue and user manual. Processor and memory descriptions come from Microchip's AT91SAM9G20 page and Renesas's R5F1017A page. The 2008 introduction and the 2017 acquisition dates come from Omron's own announcements. The 2015 date code was read from the marking on the processor package. The teardown's claims about laser illumination, the memory maker's parent company and the Microscan lineage are contradicted by those sources and are flagged in place rather than repeated.
The reader was not powered on, and no measurement in this article was taken from a working unit.