A battery-powered Zigbee 3.0 sensor that measures temperature and relative humidity and shows both on a 2.8-inch LCD. It reports over Zigbee only; there is no Wi-Fi radio and no cloud account in the device itself.
The published ranges are minus 9.9 to 60 degrees Celsius and 5 to 95 per cent relative humidity, non-condensing. The comfort thresholds are display settings, not sensor limits.
Temperature is published in Celsius through the bridge; the display unit can be changed to Fahrenheit, and calibration offsets exist for both temperature and humidity. A calibration offset is a correction you apply deliberately after comparing against a reference, not a fix for a badly placed sensor.
Placement matters more than calibration. A sensor above a radiator, in direct sun or next to a kettle reports the surface it sits on.
Read the quick start for pairing and for the wake-before-write sequence, and the MQTT chapter for the topic layout and the availability defaults that apply to battery devices.
This profile is based on official documentation, not our own device testing.
This sequence takes one sensor from the box to a readable temperature and humidity topic, with the battery device behaviour that trips most first attempts made explicit.
The sensor takes a CR2450 coin cell. Close the case fully before pairing; a partially seated cell produces a device that joins and then drops.
Enable permit-join in Zigbee2MQTT, or start the add-device flow in your Zigbee integration. The window should be open before the sensor is triggered, because a passive device only announces itself when woken.
Trigger pairing as the vendor instructions describe, then watch the join log. Name the device at join time: the friendly name becomes the MQTT topic segment, and renaming later moves every topic an automation already uses.
Open the device page and confirm temperature, humidity and battery level. Then wait for a live report rather than trusting the value that appears immediately: a retained snapshot has no observation time attached.
Every writable attribute carries the same vendor note: press the button on the back to wake the device before changing the value. A sleeping end device does not hear the write, and the bridge reports the command as sent while nothing changes.
The reliable order is: press the button, wait for a fresh report, publish the change, then read the value back.
Temperature unit, comfort minimum and maximum for both temperature and humidity, and the two calibration offsets are display and reporting settings. An automation that needs a comfort rule should compute it from the readings instead.
Compare against a known reference in the same position for a few hours before applying an offset. A hasty offset hides a placement problem and follows the sensor to its next room.
Battery devices are passive on the Zigbee network. The bridge infers liveness from silence, and the documented default for a passive device is 1500 minutes, about 25 hours.
An unchanged reading for an hour is normal. Only the availability topic can distinguish a quiet sensor from a dead one.
The MQTT chapter covers the topic layout, the set commands and the availability configuration in detail.
This profile is based on official documentation, not our own device testing.
No. The sensor is a Zigbee end device. Without a coordinator or a hub it has nothing to join and nothing to report to.
The reporting interval is decided by the device firmware, not by the automation platform. The published material does not give a single fixed interval for every condition, so treat the arrival rate as an observation and record it before building a rule on it.
Because the device was asleep. Every writable attribute carries a vendor note to press the button on the back first. Press it, wait for a fresh report, publish the change, then read the value back.
Treat the reading as room-level monitoring, not as a control sensor. The published interface exposes calibration offsets, which implies the vendor expects small differences between units, and a battery sensor reports on its own schedule.
They change the icons on the display: a cold or hot symbol for temperature, a dry or humid symbol for humidity. They do not create alerts, and they do not affect the values sent over Zigbee.
No. It measures temperature and relative humidity only. Air-quality work needs a different sensor.
The published material describes indoor use, and the humidity range is specified as non-condensing. A balcony in winter is outside that description.
The vendor does not publish a figure that survives translation into your room, your reporting rate and your network. Plan on replacing a CR2450 when the reported battery level falls, and keep a spare on hand rather than extrapolating.
Because passive devices sleep. The documented availability default for a passive device is 1500 minutes, about 25 hours. Silence is not evidence of failure; the availability topic is the evidence.